A calibration of NICMOS camera 2 for low count rates

  • D. Rubin
  • , G. Aldering
  • , R. Amanullah
  • , K. Barbary
  • , K. S. Dawson
  • , S. Deustua
  • , L. Faccioli
  • , V. Fadeyev
  • , H. K. Fakhouri
  • , A. S. Fruchter
  • , M. D. Gladders
  • , R. S.De Jong
  • , A. Koekemoer
  • , E. Krechmer
  • , C. Lidman
  • , J. Meyers
  • , J. Nordin
  • , S. Perlmutter
  • , P. Ripoche
  • , D. J. Schlegel
  • A. Spadafora, N. Suzuki

Research output: Contribution to journal › Article › peer-review

7 Citations (Scopus)

Abstract

NICMOS 2 observations are crucial for constraining distances to most of the existing sample of z > 1 SNe Ia. Unlike conventional calibration programs, these observations involve long exposure times and low count rates. Reciprocity failure is known to exist in HgCdTe devices and a correction for this effect has already been implemented for high and medium count rates. However, observations at faint count rates rely on extrapolations. Here instead, we provide a new zero-point calibration directly applicable to faint sources. This is obtained via intercalibration of NIC2 F110W/F160W with the Wide Field Camera 3 (WFC3) in the low count-rate regime using z ∼ 1 elliptical galaxies as tertiary calibrators. These objects have relatively simple near-IR spectral energy distributions, uniform colors, and their extended nature gives a superior signal-to-noise ratio at the same count rate than would stars. The use of extended objects also allows greater tolerances on point-spread function profiles. We find space telescope magnitude zero points (after the installation of the NICMOS cooling system, NCS) of 25.296 ± 0.022 for F110W and 25.803 ± 0.023 for F160W, both in agreement with the calibration extrapolated from count rates ≳1000 times larger (25.262 and 25.799). Before the installation of the NCS, we find 24.843 ± 0.025 for F110W and 25.498 ± 0.021 for F160W, also in agreement with the high-count-rate calibration (24.815 and 25.470). We also check the standard bandpasses of WFC3 and NICMOS 2 using a range of stars and galaxies at different colors and find mild tension for WFC3, limiting the accuracy of the zero points. To avoid human bias, our cross-calibration was 'blinded' in that the fitted zero-point differences were hidden until the analysis was finalized.

Original languageEnglish
Article number159
JournalAstronomical Journal
Volume149
Issue number5
DOIs
Publication statusPublished - 1 May 2015
Externally publishedYes

Fingerprint

Dive into the research topics of 'A calibration of NICMOS camera 2 for low count rates'. Together they form a unique fingerprint.

Cite this