A long-term fading study for ESR intensity measurement and dose evaluation on fossil tooth enamel

Rainer Grün*, Kirsten Ward

*Corresponding author for this work

    Research output: Contribution to journalArticlepeer-review

    14 Citations (Scopus)

    Abstract

    Two sets of samples, originally measured in 1989 and 1995, respectively, were re-measured in 2001 to assess long-term fading of the ESR signal in fossil tooth enamel. About half of the samples of the 1989 set showed some fading of the central ESR signal, the average intensity of the irradiated aliquots of a sample decreasing by between 3% and 10%. The resulting dose values were on average between 2% and 6% larger than the original estimates. The 1995 sample set did not contain any quantifiable fading component. We infer that there may be a fading component which saturates at relatively low intensities. However, at present we are not confident that any prescribed post-irradiation annealing procedure is capable of eliminating the unstable component without affecting any other ESR parameters.

    Original languageEnglish
    Pages (from-to)269-274
    Number of pages6
    JournalRadiation Measurements
    Volume35
    Issue number3
    DOIs
    Publication statusPublished - 2002

    Fingerprint

    Dive into the research topics of 'A long-term fading study for ESR intensity measurement and dose evaluation on fossil tooth enamel'. Together they form a unique fingerprint.