Skip to main navigation Skip to search Skip to main content

A second-generation (44-channel) suprachoroidal retinal prosthesis: Interim clinical trial results

  • Matthew A. Petoe
  • , Samuel A. Titchener
  • , Maria Kolic
  • , William G. Kentler
  • , Carla J. Abbott
  • , David A.X. Nayagam
  • , Elizabeth K. Baglin
  • , Jessica Kvansakul
  • , Nick Barnes
  • , Janine G. Walker
  • , Stephanie B. Epp
  • , Kiera A. Young
  • , Lauren N. Ayton
  • , Chi D. Luu
  • , Penelope J. Allen*
  • *Corresponding author for this work

    Research output: Contribution to journal › Article › peer-review

    61 Citations (Scopus)

    Abstract

    Purpose: To report the initial safety and efficacy results of a second-generation (44-channel) suprachoroidal retinal prosthesis at 56 weeks after device activation. Methods: Four subjects, with advanced retinitis pigmentosa and bare-light perception only, enrolled in a phase II trial (NCT03406416). A 44-channel electrode array was implanted in a suprachoroidal pocket. Device stability, efficacy, and adverse events were investigated at 12-week intervals. Results: All four subjects were implanted successfully and there were no device-related serious adverse events. Color fundus photography indicated a mild postoperative subretinal hemorrhage in two recipients, which cleared spontaneously within 2 weeks. Optical coherence tomography confirmed device stability and position under the macula. Screen-based localization accuracy was significantly better for all subjects with device on versus device off. Two subjects were significantly better with the device on in a motion discrimination task at 7, 15, and 30°/s and in a spatial discrimination task at 0.033 cycles per degree. All subjects were more accurate with the device on than device off at walking toward a target on a modified door task, localizing and touching tabletop objects, and detecting obstacles in an obstacle avoidance task. A positive effect of the implant on subjects’ daily lives was confirmed by an orientation and mobility assessor and subject self-report. Conclusions: These interim study data demonstrate that the suprachoroidal prosthesis is safe and provides significant improvements in functional vision, activities of daily living, and observer-rated quality of life. Translational Relevance: A suprachoroidal prosthesis can provide clinically useful artificial vision while maintaining a safe surgical profile.

    Original languageEnglish
    Article number12
    JournalTranslational Vision Science and Technology
    Volume10
    Issue number10
    DOIs
    Publication statusPublished - Aug 2021

    Fingerprint

    Dive into the research topics of 'A second-generation (44-channel) suprachoroidal retinal prosthesis: Interim clinical trial results'. Together they form a unique fingerprint.

    Cite this