TY - JOUR
T1 - A universal approach for continuum solvent pKa calculations
T2 - Are we there yet?
AU - Ho, Junming
AU - Coote, Michelle L.
PY - 2009/1
Y1 - 2009/1
N2 - This paper reviews several pKa calculation strategies that are commonly used in aqueous acidity predictions. Among those investigated were the direct or absolute method, the proton exchange scheme, and the hybrid cluster-continuum (Pliego and Riveros) and implicit-explicit (Kelly, Cramer and Truhlar) models. Additionally, these protocols are applied in the pKa calculation of 55 neutral organic and inorganic acids in conjunction with various solvent models, including the CPCM-UAKS/UAHF, IPCM, SM6 and COSMO-RS, with a view to identifying a universal approach for accurate pKa predictions. The results indicate that the direct method is unsuitable for general pKa calculations, although moderately accurate results (MAD <3 units) are possible for certain classes of acids, depending on the choice of solvent model. The proton exchange scheme generally delivers good results (MAD <2 units), with CPCM-UAKS giving the best performance. Furthermore, the sensitivity of this approach to the choice of reference acid can be substantially lessened if the solvation energies for ionic species are calculated via the IPCM cluster-continuum approach. Reference-independent hybrid approaches that include explicit water molecules can potentially give reasonably accurate values (MAD generally 2 units) depending on the solvent model and the number of explicit water molecules added.
AB - This paper reviews several pKa calculation strategies that are commonly used in aqueous acidity predictions. Among those investigated were the direct or absolute method, the proton exchange scheme, and the hybrid cluster-continuum (Pliego and Riveros) and implicit-explicit (Kelly, Cramer and Truhlar) models. Additionally, these protocols are applied in the pKa calculation of 55 neutral organic and inorganic acids in conjunction with various solvent models, including the CPCM-UAKS/UAHF, IPCM, SM6 and COSMO-RS, with a view to identifying a universal approach for accurate pKa predictions. The results indicate that the direct method is unsuitable for general pKa calculations, although moderately accurate results (MAD <3 units) are possible for certain classes of acids, depending on the choice of solvent model. The proton exchange scheme generally delivers good results (MAD <2 units), with CPCM-UAKS giving the best performance. Furthermore, the sensitivity of this approach to the choice of reference acid can be substantially lessened if the solvation energies for ionic species are calculated via the IPCM cluster-continuum approach. Reference-independent hybrid approaches that include explicit water molecules can potentially give reasonably accurate values (MAD generally 2 units) depending on the solvent model and the number of explicit water molecules added.
KW - Cluster-continuum model
KW - Continuum solvent model
KW - Proton exchange method
KW - pK calculation
UR - http://www.scopus.com/inward/record.url?scp=73949145040&partnerID=8YFLogxK
U2 - 10.1007/s00214-009-0667-0
DO - 10.1007/s00214-009-0667-0
M3 - Article
SN - 1432-881X
VL - 125
SP - 3
EP - 21
JO - Theoretical Chemistry Accounts
JF - Theoretical Chemistry Accounts
IS - 1
ER -