TY - JOUR
T1 - Background reduction in 236U/238U measurements
AU - Buompane, Raffaele
AU - De Cesare, Mario
AU - De Cesare, Nicola
AU - Di Leva, Antonino
AU - D'Onofrio, Antonio
AU - Fifield, L. Keith
AU - Fröhlich, Michaela
AU - Gialanella, Lucio
AU - Marzaioli, Fabio
AU - Sabbarese, Carlo
AU - Terrasi, Filippo
AU - Tims, Stephen
AU - Wallner, Anton
N1 - Publisher Copyright:
© 2015 Elsevier B.V. All rights reserved.
PY - 2015/10/15
Y1 - 2015/10/15
N2 - The measurements of actinide isotopic ratios, in particular 236U/238U, in environmental samples requires high sensitivity. In particular, special effort must be devoted to the suppression of interfering nuclides, such as 235,238U, when measuring 236U. At the AMS facility of CIRCE, isotopic ratios down to ∼10-10 are currently measured using a gas E - ΔE detector. In order to push this limit lower towards natural levels, a time-of-flight system is used, featuring a micro-channel plate start detector and a Si stop detector. As the mass resolution of the latter is limited by the layout, an attempt to reduce the abundant isotope interference by other means has been undertaken. In this study, we report preliminary results on the characterization of the presence of molecular interferences when using UO-, UC- and UC2- as injected molecular ions. In particular the possibility to stabilize the current yield from carbide cathodes has been investigated: it was found that the best cathode preparation procedure is obtained pressing U salts baked at 800 °C mixed with graphite and Al powder. Moreover, the 238U background in 236U measurements is strongly reduced injecting UC- ions, as verified using a time-of-flight detection system. On the other hand, 235U interference is larger with respect to UO- injection, but this increase is smaller than expected on the basis of abundances of 13C and 17O in UC and UC2 molecules on one side and UO, on the other.
AB - The measurements of actinide isotopic ratios, in particular 236U/238U, in environmental samples requires high sensitivity. In particular, special effort must be devoted to the suppression of interfering nuclides, such as 235,238U, when measuring 236U. At the AMS facility of CIRCE, isotopic ratios down to ∼10-10 are currently measured using a gas E - ΔE detector. In order to push this limit lower towards natural levels, a time-of-flight system is used, featuring a micro-channel plate start detector and a Si stop detector. As the mass resolution of the latter is limited by the layout, an attempt to reduce the abundant isotope interference by other means has been undertaken. In this study, we report preliminary results on the characterization of the presence of molecular interferences when using UO-, UC- and UC2- as injected molecular ions. In particular the possibility to stabilize the current yield from carbide cathodes has been investigated: it was found that the best cathode preparation procedure is obtained pressing U salts baked at 800 °C mixed with graphite and Al powder. Moreover, the 238U background in 236U measurements is strongly reduced injecting UC- ions, as verified using a time-of-flight detection system. On the other hand, 235U interference is larger with respect to UO- injection, but this increase is smaller than expected on the basis of abundances of 13C and 17O in UC and UC2 molecules on one side and UO, on the other.
KW - AMS
KW - Background
KW - Isotopic ratio
KW - Uranium
KW - Uranium carbide
UR - http://www.scopus.com/inward/record.url?scp=84943455568&partnerID=8YFLogxK
U2 - 10.1016/j.nimb.2015.04.003
DO - 10.1016/j.nimb.2015.04.003
M3 - Article
SN - 0168-583X
VL - 361
SP - 454
EP - 457
JO - Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms
JF - Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms
ER -