TY - JOUR
T1 - Cerebrospinal fluid pressure in adults
AU - Lee, Sarah C.M.
AU - Lueck, Christian J.
PY - 2014
Y1 - 2014
N2 - BACKGROUND:: Lumbar puncture (LP) is a widely-used investigative procedure. It allows relatively non-invasive measurement of intracranial pressure (ICP) which may have a significant impact on diagnosis and/or patient management. Over the years there has been considerable discussion about various aspects of the procedure, including what constitutes a normal opening pressure, what factors might influence this, and how LP is best performed. EVIDENCE ACQUISITION:: A review of the literature was carried out by searching PubMed and Medline, scanning relevant medical journals for recent publications, and carrying out secondary referencing and contacting other clinicians, where appropriate. RESULTS:: The normal range of ICP measured by LP in adults in a typical clinical setting should now be regarded as 6 to 25 cmH2O (95% confidence intervals), with a population mean of about 18 cmH2O. There is, however, considerable variability: some normal individuals have pressures of 30 cmH2O (or, occasionally, even higher) meaning that pressure measurements must be interpreted in the clinical context. CONCLUSIONS:: This article aims to provide the practicing neuro-ophthalmologist with up-to-date information about the ways in which various factors can influence pressure measurements obtained at LP.
AB - BACKGROUND:: Lumbar puncture (LP) is a widely-used investigative procedure. It allows relatively non-invasive measurement of intracranial pressure (ICP) which may have a significant impact on diagnosis and/or patient management. Over the years there has been considerable discussion about various aspects of the procedure, including what constitutes a normal opening pressure, what factors might influence this, and how LP is best performed. EVIDENCE ACQUISITION:: A review of the literature was carried out by searching PubMed and Medline, scanning relevant medical journals for recent publications, and carrying out secondary referencing and contacting other clinicians, where appropriate. RESULTS:: The normal range of ICP measured by LP in adults in a typical clinical setting should now be regarded as 6 to 25 cmH2O (95% confidence intervals), with a population mean of about 18 cmH2O. There is, however, considerable variability: some normal individuals have pressures of 30 cmH2O (or, occasionally, even higher) meaning that pressure measurements must be interpreted in the clinical context. CONCLUSIONS:: This article aims to provide the practicing neuro-ophthalmologist with up-to-date information about the ways in which various factors can influence pressure measurements obtained at LP.
UR - http://www.scopus.com/inward/record.url?scp=84906820344&partnerID=8YFLogxK
U2 - 10.1097/WNO.0000000000000155
DO - 10.1097/WNO.0000000000000155
M3 - Review article
SN - 1070-8022
VL - 34
SP - 278
EP - 283
JO - Journal of Neuro-Ophthalmology
JF - Journal of Neuro-Ophthalmology
IS - 3
ER -