TY - JOUR
T1 - Concordance between core needle biopsy and surgical excision for breast cancer tumor grade and biomarkers
AU - Shanmugalingam, Aswin
AU - Hitos, Kerry
AU - Hegde, Shrenik
AU - Al-Mashat, Ali
AU - Pathmanathan, Nirmala
AU - Edirimmane, Senarath
AU - Hughes, T. Michael
AU - Ngui, Nicholas K.
N1 - Publisher Copyright:
© 2022, The Author(s), under exclusive licence to Springer Science+Business Media, LLC, part of Springer Nature.
PY - 2022/5
Y1 - 2022/5
N2 - Purpose: Histopathological biomarkers guide breast cancer management. Testing histopathological biomarkers on both core needle biopsy (CNB) and surgical excision (SE) in patients who are treated with upfront surgery is unnecessary and costly if there is high concordance between the two. This study investigated the concordance between CNB and SE for estrogen receptor (ER), progesterone receptor (PR), human epidermal growth factor-2 (HER2), tumor grade and Ki-67. Methods: Histopathological biomarker information were retrospectively collected from preoperative CNB and SE on patients diagnosed with breast cancer through the BreastScreen Sydney West program over a four-year period between January 2017 and December 2020. Data were then analyzed to calculate percentage of agreement and concordance using kappa values for ER, PR, HER2, tumor grade and Ki-67. Results: A total of 504 cases of invasive breast cancers were analyzed. There was substantial level of concordance for ER 96.7% (κ = 0.687) and PR 93.2% (κ = 0.69). Concordance for HER2 negative (IHC 0, IHC 1 +) or positive (IHC 3 +) tumor on CNB was 100% (κ = 1.00). Grade and Ki-67 showed moderate level of concordance, 72.6% (κ = 0.545) and 70.5% (κ = 0.453), respectively. Conclusion: ER, PR and HER2 show high level of concordance. CNB is reliable in determining histopathological biomarkers for ER, PR positive and HER2 positive or negative tumors indicating that retesting these on SE may not be necessary.
AB - Purpose: Histopathological biomarkers guide breast cancer management. Testing histopathological biomarkers on both core needle biopsy (CNB) and surgical excision (SE) in patients who are treated with upfront surgery is unnecessary and costly if there is high concordance between the two. This study investigated the concordance between CNB and SE for estrogen receptor (ER), progesterone receptor (PR), human epidermal growth factor-2 (HER2), tumor grade and Ki-67. Methods: Histopathological biomarker information were retrospectively collected from preoperative CNB and SE on patients diagnosed with breast cancer through the BreastScreen Sydney West program over a four-year period between January 2017 and December 2020. Data were then analyzed to calculate percentage of agreement and concordance using kappa values for ER, PR, HER2, tumor grade and Ki-67. Results: A total of 504 cases of invasive breast cancers were analyzed. There was substantial level of concordance for ER 96.7% (κ = 0.687) and PR 93.2% (κ = 0.69). Concordance for HER2 negative (IHC 0, IHC 1 +) or positive (IHC 3 +) tumor on CNB was 100% (κ = 1.00). Grade and Ki-67 showed moderate level of concordance, 72.6% (κ = 0.545) and 70.5% (κ = 0.453), respectively. Conclusion: ER, PR and HER2 show high level of concordance. CNB is reliable in determining histopathological biomarkers for ER, PR positive and HER2 positive or negative tumors indicating that retesting these on SE may not be necessary.
KW - Biomarkers
KW - Breast cancer
KW - Core needle biopsy
KW - Estrogen receptor
KW - Human epidermal growth factor-2
KW - Ki-67
KW - Progesterone receptor
KW - Surgical excision
KW - Tumor grade
UR - http://www.scopus.com/inward/record.url?scp=85125366383&partnerID=8YFLogxK
U2 - 10.1007/s10549-022-06548-w
DO - 10.1007/s10549-022-06548-w
M3 - Article
SN - 0167-6806
VL - 193
SP - 151
EP - 159
JO - Breast Cancer Research and Treatment
JF - Breast Cancer Research and Treatment
IS - 1
ER -