CSF opening pressure: Reference interval and the effect of body mass index

W. Whiteley*, R. Al-Shahi, C. P. Warlow, M. Zeidler, C. J. Lueck

*Corresponding author for this work

    Research output: Contribution to journalArticlepeer-review

    181 Citations (Scopus)

    Abstract

    We prospectively recorded CSF opening pressure in 242 adults who had a lumbar puncture with concomitant measurement of weight and height. The 95% reference interval for lumbar CSF opening pressure was 10 to 25 cm CSF. Body mass index had a small but clinically insignificant influence on CSF opening pressure.

    Original languageEnglish
    Pages (from-to)1690-1691
    Number of pages2
    JournalNeurology
    Volume67
    Issue number9
    DOIs
    Publication statusPublished - Nov 2006

    Fingerprint

    Dive into the research topics of 'CSF opening pressure: Reference interval and the effect of body mass index'. Together they form a unique fingerprint.