TY - JOUR
T1 - Electronic band structure of beryllium oxide
AU - Sashin, V. A.
AU - Bolorizadeh, M. A.
AU - Kheifets, A. S.
AU - Ford, M. J.
PY - 2003/6/4
Y1 - 2003/6/4
N2 - Atomic and Molecular Physics Laboratories, Research School of Physical Sciences and Engineering, The Australian National University, Canberra ACT 0200, Australia. The energy-momentum resolved valence band structure of beryllium oxide has been measured by electron momentum spectroscopy (EMS). Band dispersions, bandwidths and intervalence bandgap, electron momentum density (EMD) and density of occupied states have been extracted from the EMS data. The experimental results are compared with band structure calculations performed within the full potential linear muffin-tin orbital approximation. Our experimental bandwidths of 2.1 ± 0.2 and 4.8 ± 0.3 eV for the oxygen s and p bands, respectively, are in accord with theoretical predictions, as is the s-band EMD after background subtraction. Contrary to the calculations, however, the measured p-band EMD shows large intensity at the Γ point. The measured full valence bandwidth of 19.4 ± 0.3 eV is at least 1.4 eV larger than the theory. The experiment also finds a significantly higher value for the p-to-s-band EMD ratio in a broad momentum range compared to the theory.
AB - Atomic and Molecular Physics Laboratories, Research School of Physical Sciences and Engineering, The Australian National University, Canberra ACT 0200, Australia. The energy-momentum resolved valence band structure of beryllium oxide has been measured by electron momentum spectroscopy (EMS). Band dispersions, bandwidths and intervalence bandgap, electron momentum density (EMD) and density of occupied states have been extracted from the EMS data. The experimental results are compared with band structure calculations performed within the full potential linear muffin-tin orbital approximation. Our experimental bandwidths of 2.1 ± 0.2 and 4.8 ± 0.3 eV for the oxygen s and p bands, respectively, are in accord with theoretical predictions, as is the s-band EMD after background subtraction. Contrary to the calculations, however, the measured p-band EMD shows large intensity at the Γ point. The measured full valence bandwidth of 19.4 ± 0.3 eV is at least 1.4 eV larger than the theory. The experiment also finds a significantly higher value for the p-to-s-band EMD ratio in a broad momentum range compared to the theory.
UR - http://www.scopus.com/inward/record.url?scp=0038170500&partnerID=8YFLogxK
U2 - 10.1088/0953-8984/15/21/306
DO - 10.1088/0953-8984/15/21/306
M3 - Article
SN - 0953-8984
VL - 15
SP - 3567
EP - 3581
JO - Journal of Physics Condensed Matter
JF - Journal of Physics Condensed Matter
IS - 21
ER -