Abstract
Sagnac interferometers have recently been proposed as a potential alternative to Michelson interferometers for the purpose of large-scale laser interferometric gravitational-wave detectors. We report on an experimental investigation of the Sagnac interferometer in two configurations: with arm cavities, and with resonant sideband extraction. Resonant sideband extraction was shown to increase the signal bandwidth by a factor of 6.5 compared with the arm cavity device, corresponding to an increase in sensitivity of as much as 6 dB for signals outside the arm cavity bandwidth. Moreover, we compare the performance of a Sagnac interferometer with resonant sideband extraction to a Michelson interferometer with resonant sideband extraction.
| Original language | English |
|---|---|
| Pages (from-to) | 7995-8001 |
| Number of pages | 7 |
| Journal | Applied Optics |
| Volume | 37 |
| Issue number | 34 |
| DOIs | |
| Publication status | Published - 1 Dec 1998 |
Fingerprint
Dive into the research topics of 'Experimental demonstration of resonant sideband extraction in a sagnac interferometer'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver