In vivo tumour imaging employing regional delivery of novel gallium radiolabelled polymer composites

Ross W. Stephens*, Gregory D. Tredwell, Jessica L. Bell, Karen J. Knox, Lee A. Philip, Tim J. Senden, Michael J. Tapner, Stephanie A. Bickley, Marcel R. Tanudji, Stephen K. Jones

*Corresponding author for this work

    Research output: Contribution to journalArticlepeer-review

    1 Citation (Scopus)

    Abstract

    Background: Understanding the regional vascular delivery of particles to tumour sites is a prerequisite for developing new diagnostic and therapeutic composites for treatment of oncology patients. We describe a novel imageable 67Ga-radiolabelled polymer composite that is biocompatible in an animal tumour model and can be used for preclinical imaging investigations of the transit of different sized particles through arterial networks of normal and tumour-bearing organs. Results: Radiolabelling of polymer microspheres with 67Ga was achieved using a simple mix and wash method, with tannic acid as an immobilising agent. Final in vitro binding yields after autoclaving averaged 94.7%. In vivo stability of the composite was demonstrated in New Zealand white rabbits by intravenous administration, and intrahepatic artery instillations were made in normal and VX2 tumour implanted rabbit livers. Stability of radiolabel was sufficient for rabbit lung and liver imaging over at least 3 hours and 1 hour respectively, with lung retention of radiolabel over 91%, and retention in both normal and VX2 implanted livers of over 95%. SPECT-CT imaging of anaesthetised animals and planar imaging of excised livers showed visible accumulation of radiolabel in tumours. Importantly, microsphere administration and complete liver dispersal was more easily achieved with 8 μm diameter MS than with 30 μm MS, and the smaller microspheres provided more distinct and localised tumour imaging. Conclusion: This method of producing 67Ga-radiolabelled polymer microspheres is suitable for SPECT-CT imaging of the regional vascular delivery of microspheres to tumour sites in animal models. Sharper distinction of model tumours from normal liver was obtained with smaller MS, and tumour resolution may be further improved by the use of 68Ga instead of 67Ga, to enable PET imaging.

    Original languageEnglish
    Article number7
    JournalBiomaterials Research
    Volume25
    Issue number1
    DOIs
    Publication statusPublished - Dec 2021

    Fingerprint

    Dive into the research topics of 'In vivo tumour imaging employing regional delivery of novel gallium radiolabelled polymer composites'. Together they form a unique fingerprint.

    Cite this