TY - JOUR
T1 - Label-free multimodal quantitative imaging flow assay for intrathrombus formation in vitro
AU - Zheng, Yujie
AU - Montague, Samantha J.
AU - Lim, Yean J.
AU - Xu, Tao
AU - Xu, Tienan
AU - Gardiner, Elizabeth E.
AU - Lee, Woei Ming
N1 - Publisher Copyright:
© 2021 Biophysical Society
PY - 2021/3/2
Y1 - 2021/3/2
N2 - Microfluidics in vitro assays recapitulate a blood vessel microenvironment using surface-immobilized agonists under biofluidic flows. However, these assays do not quantify intrathrombus mass and activities of adhesive platelets at the agonist margin and use fluorescence labeling, therefore limiting clinical translation potential. Here, we describe a label-free multimodal quantitative imaging flow assay that combines rotating optical coherent scattering microscopy and quantitative phase microscopy. The combined imaging platform enables real-time evaluation of membrane fluctuations of adhesive-only platelets and total intrathrombus mass under physiological flow rates in vitro. We call this multimodal quantitative imaging flow assay coherent optical scattering and phase interferometry (COSI). COSI records intrathrombus mass to picogram accuracy and shape changes to a platelet membrane with high spatial-temporal resolution (0.4 μm/s) under physiological and pathophysiological fluid shear stress (1800 and 7500 s−1). With COSI, we generate an axial slice of 4 μm from the coverslip surface, approximately equivalent to the thickness of a single platelet, which permits nanoscale quantification of membrane fluctuation (activity) of adhesive platelets during initial adhesion, spreading, and recruitment into a developing thrombus (mass). Under fluid shear, pretreatment with a broad range metalloproteinase inhibitor (250 μM GM6001) blocked shedding of platelet adhesion receptors that shown elevated adhesive platelet activity at average of 42.1 μm/s and minimal change in intrathrombus mass.
AB - Microfluidics in vitro assays recapitulate a blood vessel microenvironment using surface-immobilized agonists under biofluidic flows. However, these assays do not quantify intrathrombus mass and activities of adhesive platelets at the agonist margin and use fluorescence labeling, therefore limiting clinical translation potential. Here, we describe a label-free multimodal quantitative imaging flow assay that combines rotating optical coherent scattering microscopy and quantitative phase microscopy. The combined imaging platform enables real-time evaluation of membrane fluctuations of adhesive-only platelets and total intrathrombus mass under physiological flow rates in vitro. We call this multimodal quantitative imaging flow assay coherent optical scattering and phase interferometry (COSI). COSI records intrathrombus mass to picogram accuracy and shape changes to a platelet membrane with high spatial-temporal resolution (0.4 μm/s) under physiological and pathophysiological fluid shear stress (1800 and 7500 s−1). With COSI, we generate an axial slice of 4 μm from the coverslip surface, approximately equivalent to the thickness of a single platelet, which permits nanoscale quantification of membrane fluctuation (activity) of adhesive platelets during initial adhesion, spreading, and recruitment into a developing thrombus (mass). Under fluid shear, pretreatment with a broad range metalloproteinase inhibitor (250 μM GM6001) blocked shedding of platelet adhesion receptors that shown elevated adhesive platelet activity at average of 42.1 μm/s and minimal change in intrathrombus mass.
UR - http://www.scopus.com/inward/record.url?scp=85100770595&partnerID=8YFLogxK
U2 - 10.1016/j.bpj.2021.01.015
DO - 10.1016/j.bpj.2021.01.015
M3 - Article
SN - 0006-3495
VL - 120
SP - 791
EP - 804
JO - Biophysical Journal
JF - Biophysical Journal
IS - 5
ER -