TY - JOUR
T1 - Measurement of 236U on the 1 MV AMS system at the Centro Nacional de Aceleradores (CNA)
AU - Chamizo, E.
AU - Christl, M.
AU - Fifield, L. K.
N1 - Publisher Copyright:
© 2015 Elsevier B.V.
PY - 2015/5/27
Y1 - 2015/5/27
N2 - In this paper we present the first comprehensive analysis of the 1 MV AMS system at the Centro Nacional de Aceleradores (CNA, Seville, Spain) for 236U studies in environmental samples. In the last years, this radionuclide has become key in the AMS community, due to the very demanding 236U/238U abundance sensitivities required for general applications. As we demonstrate, the AMS system at the CNA is able to achieve sensitivity for the 236U/238U ratio of about 3 × 10-11 despite its compact design. The use of "239Pu"/238U ratio as a proxy for "236U"/235U background correction is proposed and tested with natural samples that were also studied on the 600 kV Tandy AMS system at the ETH Zürich. This correction is significant in the CNA case, due to the low mass resolving power of the low-energy spectrometer and to the lack of a third filter on the high-energy side. With the measurement of reference solutions supplied by the Institute for Reference Materials and Methods (IRMM-075), and reference natural matrixes provided by the International Atomic Energy Agency (IAEA-Soil-6, IAEA-375; 384; 386 and IAEA-RGU), we show that the 1 MV AMS system at the CNA can be routinely used for determinations of anthropogenic 236U at environmental levels.
AB - In this paper we present the first comprehensive analysis of the 1 MV AMS system at the Centro Nacional de Aceleradores (CNA, Seville, Spain) for 236U studies in environmental samples. In the last years, this radionuclide has become key in the AMS community, due to the very demanding 236U/238U abundance sensitivities required for general applications. As we demonstrate, the AMS system at the CNA is able to achieve sensitivity for the 236U/238U ratio of about 3 × 10-11 despite its compact design. The use of "239Pu"/238U ratio as a proxy for "236U"/235U background correction is proposed and tested with natural samples that were also studied on the 600 kV Tandy AMS system at the ETH Zürich. This correction is significant in the CNA case, due to the low mass resolving power of the low-energy spectrometer and to the lack of a third filter on the high-energy side. With the measurement of reference solutions supplied by the Institute for Reference Materials and Methods (IRMM-075), and reference natural matrixes provided by the International Atomic Energy Agency (IAEA-Soil-6, IAEA-375; 384; 386 and IAEA-RGU), we show that the 1 MV AMS system at the CNA can be routinely used for determinations of anthropogenic 236U at environmental levels.
KW - AMS
KW - Compact AMS facilities
KW - U-236
KW - Uranium
UR - http://www.scopus.com/inward/record.url?scp=84930196372&partnerID=8YFLogxK
U2 - 10.1016/j.nimb.2015.05.008
DO - 10.1016/j.nimb.2015.05.008
M3 - Article
SN - 0168-583X
VL - 358
SP - 45
EP - 51
JO - Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms
JF - Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms
ER -