TY - JOUR
T1 - Mimir
T2 - A near-infrared wide-field imager, spectrometer, and polarimeter
AU - Clemens, D. P.
AU - Sarcia, D.
AU - Grabau, A.
AU - Tollestrup, E. V.
AU - Buie, M. W.
AU - Dunham, E.
AU - Taylor, B.
PY - 2007/12
Y1 - 2007/12
N2 - Mimir, a new facility-class near-infrared instrument for the 1.8 m Perkins telescope on Anderson Mesa outside Flagstaff, Arizona, was commissioned and has been operating for three years. Mimir is multifunction, performing wide-field (F/5) and narrow-field (F/17) imaging, long-slit spectroscopy, and imaging polarimetry. The F/5 mode images at 0.59″ per pixel onto the 1024 x 1024 pixel ALADDIN III InSb array detector, giving a 10′ x 10′ field of view. In the F/17 mode, the plate scale is 0.18″ per pixel. Optically, Mimir is a refractive reimager for the F/17:5 Perkins beam. A six-lens collimator produces an achromatic 25 mm pupil, which is imaged by a five-lens camera (F/5), a four-lens camera (F/17), or a two-lens pupil viewer onto the detector. Three filter wheels precede the pupil, one follows the pupil. The wheels contain a rotating half-wave plate, broadband filters, narrowband filters, grisms, long-pass filters, a wire grid, and thermal IR blockers. The first telescope focus is within Mimir, where a slit and decker unit, consisting of two linear motion cars, selects one of 13 slit scenes. The slit and decker cars, the four filter wheels, the half-wave plate rotation, and the camera selector are all driven by stepper motors within the cold vacuum space. Cooling is provided by a CTI 1050 two-stage, closed-cycle helium refrigerator, keeping the optics, filters, and internal surfaces between 65 and 75 K and the detector at 33.5 K. Switching between Mimir's different modes takes only a few seconds, making it a versatile tool for conducting a wide range of investigations and for quickly reacting to changing observing conditions. Mimir on the Perkins telescope achieves imaging sensitivities 2-4 mag deeper than 2MASS, moderate resolution (R ∼ 700) JHK spectra of virtually any 2MASS source, high-precision wide-field imaging polarimetry, and L′ and M′ band imaging and spectroscopy.
AB - Mimir, a new facility-class near-infrared instrument for the 1.8 m Perkins telescope on Anderson Mesa outside Flagstaff, Arizona, was commissioned and has been operating for three years. Mimir is multifunction, performing wide-field (F/5) and narrow-field (F/17) imaging, long-slit spectroscopy, and imaging polarimetry. The F/5 mode images at 0.59″ per pixel onto the 1024 x 1024 pixel ALADDIN III InSb array detector, giving a 10′ x 10′ field of view. In the F/17 mode, the plate scale is 0.18″ per pixel. Optically, Mimir is a refractive reimager for the F/17:5 Perkins beam. A six-lens collimator produces an achromatic 25 mm pupil, which is imaged by a five-lens camera (F/5), a four-lens camera (F/17), or a two-lens pupil viewer onto the detector. Three filter wheels precede the pupil, one follows the pupil. The wheels contain a rotating half-wave plate, broadband filters, narrowband filters, grisms, long-pass filters, a wire grid, and thermal IR blockers. The first telescope focus is within Mimir, where a slit and decker unit, consisting of two linear motion cars, selects one of 13 slit scenes. The slit and decker cars, the four filter wheels, the half-wave plate rotation, and the camera selector are all driven by stepper motors within the cold vacuum space. Cooling is provided by a CTI 1050 two-stage, closed-cycle helium refrigerator, keeping the optics, filters, and internal surfaces between 65 and 75 K and the detector at 33.5 K. Switching between Mimir's different modes takes only a few seconds, making it a versatile tool for conducting a wide range of investigations and for quickly reacting to changing observing conditions. Mimir on the Perkins telescope achieves imaging sensitivities 2-4 mag deeper than 2MASS, moderate resolution (R ∼ 700) JHK spectra of virtually any 2MASS source, high-precision wide-field imaging polarimetry, and L′ and M′ band imaging and spectroscopy.
UR - http://www.scopus.com/inward/record.url?scp=49249088067&partnerID=8YFLogxK
U2 - 10.1086/524775
DO - 10.1086/524775
M3 - Article
AN - SCOPUS:49249088067
SN - 0004-6280
VL - 119
SP - 1385
EP - 1402
JO - Publications of the Astronomical Society of the Pacific
JF - Publications of the Astronomical Society of the Pacific
IS - 862
ER -