Optimisation of laser and mass spectrometer parameters for the<i>in situ</i>analysis of Rb/Sr ratios by LA-ICP-MS/MS

Lauren Gorojovsky, Olivier Alard

Research output: Contribution to journalArticlepeer-review

50 Citations (Scopus)

Abstract

The Rb-Sr isotopic system is widely used in geochronology. Conventionally burdened by the isobaric overlap of(87)Rb and(87)Sr, Rb/Sr datingin situhas only recently become achievable with the newly developed LA-ICP-MS/MS system. Simultaneous use of reactive gas (e.g.O-2, N2O, or CH3F) during LA-ICP-MS/MS analysis has been shown to resolve the Rb and Sr overlap, thus now making available key spatial and temporal information that can only be accessedvia in situanalytical techniques. The accuracy and precision of Rb/Sr ratios and ages are largely dependent on the laser and ICP-MS/MS parameters used. Rb/Sr isotopic analysis by LA-ICP-MS/MS is a recently developed technique and these parameters are yet to be fully explored. We investigate the effects of laser wavelength (213 nm and 193 nm), laser frequency (5 Hz and 10 Hz), laser carrier gas (He, H-2, and N-2), dwell time, and external standard calibration on the accuracy and precision of(87)Rb/Sr-86 and(87)Sr/Sr-86 ratios and ages. These analytical conditions have been tested on the commercially available reference materials: NIST SRM 610, USGS BHVO-2G, and pressed nano-particulate powder tablet CRPG Mica-mg, as well as a Monastery phlogopite megacryst. Our results show that accuracy and precision for(87)Rb/Sr-86 and(87)Sr/Sr-86 ratios are significantly affected by laser wavelength and frequency. Variation in these parameters can strongly magnify any matrix effects which directly influences the ability to apply effective external corrections. We obtain the best accuracy and precision when using a 193 nm laser wavelength, ablating at a frequency of 5 Hz (0.30 2s% and 0.15 2s% for(87)Rb/Sr-86 and(87)Sr/Sr-86 ratios, respectively). Meanwhile we find that age accuracy is highly dependant on external reference materials. When these analytical settings are put to test on the Monastery phlogopite, we obtain an age of 90.0 +/- 3.6 (0.24% accuracy) when using mica-mg (Rb-87/Sr-86) and NIST 610 (Sr-87/Sr-86) as external standards.
Original languageEnglish
Pages (from-to)2322-2336
Number of pages15
JournalJournal of Analytical Atomic Spectrometry
Volume35
Issue number10
DOIs
Publication statusPublished - 1 Oct 2020
Externally publishedYes

Fingerprint

Dive into the research topics of 'Optimisation of laser and mass spectrometer parameters for the<i>in situ</i>analysis of Rb/Sr ratios by LA-ICP-MS/MS'. Together they form a unique fingerprint.

Cite this