TY - JOUR
T1 - Significant Axial Elongation with Minimal Change in Refraction in 3- to 6-Year-Old Chinese Preschoolers
T2 - The Shenzhen Kindergarten Eye Study
AU - Guo, Xinxing
AU - Fu, Min
AU - Ding, Xiaohu
AU - Morgan, Ian G.
AU - Zeng, Yangfa
AU - He, Mingguang
N1 - Publisher Copyright:
© 2017 American Academy of Ophthalmology
PY - 2017/12
Y1 - 2017/12
N2 - Purpose To document the distribution of ocular biometry and to evaluate its associations with refraction in a group of Chinese preschoolers. Design Population-based cross-sectional study. Participants A total of 1133 preschoolers 3 to 6 years of age from 8 representative kindergartens. Methods Biometric measurements including axial length (AL), anterior chamber depth (ACD), and corneal radius of curvature (CR) were obtained from partial-coherence laser interferometry (IOL Master; Carl Zeiss Meditec, Oberkochen, Germany) before cycloplegia. Lens power (LP) and AL-to-CR ratio were calculated. Cycloplegic refraction (3 drops of 1% cyclopentolate) was measured using an autorefractor (KR8800; Topcon Corp., Tokyo, Japan), and spherical equivalent refraction (SER) was calculated. Biometric and refractive parameters were assessed as a function of age and gender. Multiple regression analysis was performed to explore the associations between refraction and ocular biometry. Main Outcome Measures Ocular biometric distributions and their relationships to refraction. Results Among the 1127 children (99.5%) with successful cycloplegic refraction, mean SER was 1.37±0.63 diopters (D). Prevalence of myopia increased from 0% at 3 years of age to 3.7% (95% confidence interval, 1.0%–6.5%) at 6 years of age. Biometric parameters followed Gaussian distributions with means of 22.39±0.68 mm for AL, 7.79±0.25 mm for CR, and 24.61±1.42 D for calculated LP; and non-Gaussian distributions with means of 3.34±0.24 mm for ACD and 2.88±0.06 for AL-to-CR ratio. Axial length, ACD, and AL-to-CR ratio increased from 3 to 6 years of age, CR remained stable, whereas LP declined. Overall, SER declined slightly. For the SER variance, AL explained 18.6% and AL-to-CR ratio explained 39.8%, whereas AL, CR, and LP accounted for 80.0% after adjusting for age and gender. Conclusions Young Chinese children are predominantly mildly hyperopic, with a low prevalence of myopia by the age of 6 years. An increase of 1 mm in AL was associated with only 0.45 D of myopic change. Decreases in LP reduce the myopic shifts that normally would be associated with increases in AL, and thus play a key role in refractive development in this age group.
AB - Purpose To document the distribution of ocular biometry and to evaluate its associations with refraction in a group of Chinese preschoolers. Design Population-based cross-sectional study. Participants A total of 1133 preschoolers 3 to 6 years of age from 8 representative kindergartens. Methods Biometric measurements including axial length (AL), anterior chamber depth (ACD), and corneal radius of curvature (CR) were obtained from partial-coherence laser interferometry (IOL Master; Carl Zeiss Meditec, Oberkochen, Germany) before cycloplegia. Lens power (LP) and AL-to-CR ratio were calculated. Cycloplegic refraction (3 drops of 1% cyclopentolate) was measured using an autorefractor (KR8800; Topcon Corp., Tokyo, Japan), and spherical equivalent refraction (SER) was calculated. Biometric and refractive parameters were assessed as a function of age and gender. Multiple regression analysis was performed to explore the associations between refraction and ocular biometry. Main Outcome Measures Ocular biometric distributions and their relationships to refraction. Results Among the 1127 children (99.5%) with successful cycloplegic refraction, mean SER was 1.37±0.63 diopters (D). Prevalence of myopia increased from 0% at 3 years of age to 3.7% (95% confidence interval, 1.0%–6.5%) at 6 years of age. Biometric parameters followed Gaussian distributions with means of 22.39±0.68 mm for AL, 7.79±0.25 mm for CR, and 24.61±1.42 D for calculated LP; and non-Gaussian distributions with means of 3.34±0.24 mm for ACD and 2.88±0.06 for AL-to-CR ratio. Axial length, ACD, and AL-to-CR ratio increased from 3 to 6 years of age, CR remained stable, whereas LP declined. Overall, SER declined slightly. For the SER variance, AL explained 18.6% and AL-to-CR ratio explained 39.8%, whereas AL, CR, and LP accounted for 80.0% after adjusting for age and gender. Conclusions Young Chinese children are predominantly mildly hyperopic, with a low prevalence of myopia by the age of 6 years. An increase of 1 mm in AL was associated with only 0.45 D of myopic change. Decreases in LP reduce the myopic shifts that normally would be associated with increases in AL, and thus play a key role in refractive development in this age group.
UR - http://www.scopus.com/inward/record.url?scp=85023635294&partnerID=8YFLogxK
U2 - 10.1016/j.ophtha.2017.05.030
DO - 10.1016/j.ophtha.2017.05.030
M3 - Article
SN - 0161-6420
VL - 124
SP - 1826
EP - 1838
JO - Ophthalmology
JF - Ophthalmology
IS - 12
ER -