TY - JOUR
T1 - Storage and initial processing of water samples for organic carbon analysis in runoff
AU - Nachimuthu, Gunasekhar
AU - Watkins, Mark D.
AU - Hulugalle, Nilantha
AU - Finlay, Lloyd A.
N1 - Publisher Copyright:
© 2020
PY - 2020
Y1 - 2020
N2 - Runoff monitoring experiments are often conducted in remote sites. Sample collection and dispatch for analysis are often delayed due to sites’ remoteness and limited local laboratory facilities. The standard method of dissolved organic carbon (DOC) and total organic carbon (TOC) analysis in water samples requires storage of the samples at 4 °C after collection and analysis with a minimum of delay. However, there is no freezing storage time limit specified to avoid degradation. To overcome the limitations of this approach, we investigated the method of storage, that is refrigeration (4 °C) versus freezing (-18 °C), and the effect of storage time on DOC and TOC fractions in runoff water. Storage of samples at 4 °C for more than a week resulted in a decline of TOC and DOC concentrations in runoff water. • Freezing unfiltered water samples immediately after collection minimized TOC losses during storage, however, it may lead to variable DOC results. • Filtering a subsample of runoff or irrigation water immediately after collection using a 0.45 µm filter and freezing both the filtered and unfiltered samples until analysis of DOC and TOC, respectively, can minimize losses during storage.
AB - Runoff monitoring experiments are often conducted in remote sites. Sample collection and dispatch for analysis are often delayed due to sites’ remoteness and limited local laboratory facilities. The standard method of dissolved organic carbon (DOC) and total organic carbon (TOC) analysis in water samples requires storage of the samples at 4 °C after collection and analysis with a minimum of delay. However, there is no freezing storage time limit specified to avoid degradation. To overcome the limitations of this approach, we investigated the method of storage, that is refrigeration (4 °C) versus freezing (-18 °C), and the effect of storage time on DOC and TOC fractions in runoff water. Storage of samples at 4 °C for more than a week resulted in a decline of TOC and DOC concentrations in runoff water. • Freezing unfiltered water samples immediately after collection minimized TOC losses during storage, however, it may lead to variable DOC results. • Filtering a subsample of runoff or irrigation water immediately after collection using a 0.45 µm filter and freezing both the filtered and unfiltered samples until analysis of DOC and TOC, respectively, can minimize losses during storage.
KW - Dissolved organic carbon
KW - Freezing and thawing
KW - Storage and preservation of water samples for TOC and DOC analysis
KW - Storage time
KW - Water quality
UR - http://www.scopus.com/inward/record.url?scp=85088977739&partnerID=8YFLogxK
U2 - 10.1016/j.mex.2020.101012
DO - 10.1016/j.mex.2020.101012
M3 - Article
SN - 2215-0161
VL - 7
JO - MethodsX
JF - MethodsX
M1 - 101012
ER -