TY - JOUR
T1 - The 6dF Galaxy Survey
T2 - Bulk flows on 50-70 h-1 Mpc scales
AU - Scrimgeour, Morag I.
AU - Davis, Tamara M.
AU - Blake, Chris
AU - Staveley-Smith, Lister
AU - Magoulas, Christina
AU - Springob, Christopher M.
AU - Beutler, Florian
AU - Colless, Matthew
AU - Johnson, Andrew
AU - Heath Jones, D.
AU - Koda, Jun
AU - Lucey, John R.
AU - Ma, Yin Zhe
AU - Mould, Jeremy
AU - Poole, Gregory B.
N1 - Publisher Copyright:
© 2015 The Authors.
PY - 2016/1/1
Y1 - 2016/1/1
N2 - We measure the bulk flow of the local Universe using the 6dF Galaxy Survey peculiar velocity sample (6dFGSv), the largest and most homogeneous peculiar velocity sample to date. 6dFGSv is a Fundamental Plane sample of ~104 peculiar velocities covering the whole Southern hemisphere for galactic latitude |b| > 10°, out to redshift z = 0.0537.We apply the 'minimum variance' bulk flow weighting method, which allows us to make a robust measurement of the bulk flow on scales of 50 and 70 h-1 Mpc. We investigate and correct for potential bias due to the lognormal velocity uncertainties, and verify our method by constructing Λ cold dark matter (ΛCDM) 6dFGSv mock catalogues incorporating the survey selection function. For a hemisphere of radius 50 h-1 Mpc we find a bulk flow amplitude of U = 248 ± 58 km s-1 in the direction (l, b) = (318° ± 20°, 40° ± 13°), and for 70 h-1 Mpc we find U = 243 ± 58 km s-1, in the same direction. Our measurement gives us a constraint on σ8 of 1.01+1.07-0.58. Our results are in agreement with other recent measurements of the direction of the bulk flow, and our measured amplitude is consistent with a ΛCDM prediction.
AB - We measure the bulk flow of the local Universe using the 6dF Galaxy Survey peculiar velocity sample (6dFGSv), the largest and most homogeneous peculiar velocity sample to date. 6dFGSv is a Fundamental Plane sample of ~104 peculiar velocities covering the whole Southern hemisphere for galactic latitude |b| > 10°, out to redshift z = 0.0537.We apply the 'minimum variance' bulk flow weighting method, which allows us to make a robust measurement of the bulk flow on scales of 50 and 70 h-1 Mpc. We investigate and correct for potential bias due to the lognormal velocity uncertainties, and verify our method by constructing Λ cold dark matter (ΛCDM) 6dFGSv mock catalogues incorporating the survey selection function. For a hemisphere of radius 50 h-1 Mpc we find a bulk flow amplitude of U = 248 ± 58 km s-1 in the direction (l, b) = (318° ± 20°, 40° ± 13°), and for 70 h-1 Mpc we find U = 243 ± 58 km s-1, in the same direction. Our measurement gives us a constraint on σ8 of 1.01+1.07-0.58. Our results are in agreement with other recent measurements of the direction of the bulk flow, and our measured amplitude is consistent with a ΛCDM prediction.
KW - Cosmology
KW - Galaxies
KW - Kinematics and dynamics
KW - Large-scale structure of Universe
KW - Observations
KW - Statistics
KW - Surveys
UR - http://www.scopus.com/inward/record.url?scp=84958279460&partnerID=8YFLogxK
U2 - 10.1093/mnras/stv2146
DO - 10.1093/mnras/stv2146
M3 - Article
SN - 0035-8711
VL - 455
SP - 386
EP - 401
JO - Monthly Notices of the Royal Astronomical Society
JF - Monthly Notices of the Royal Astronomical Society
IS - 1
ER -