TY - JOUR
T1 - The Clouclip, a wearable device for measuring near-work and outdoor time
T2 - validation and comparison of objective measures with questionnaire estimates
AU - Wen, Longbo
AU - Cheng, Qian
AU - Cao, Yingpin
AU - Li, Xiaoning
AU - Pan, Lun
AU - Li, Lei
AU - Zhu, Haogang
AU - Mogran, Ian
AU - Lan, Weizhong
AU - Yang, Zhikuan
N1 - Publisher Copyright:
© 2021 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd
PY - 2021/11
Y1 - 2021/11
N2 - Purpose: To validate a novel wearable device that can measure both viewing distance and light exposure, Clouclip, and compare questionnaire estimates regarding near-work and outdoor time with the objective measures obtained using Clouclip. Methods: Fifteen Clouclips were selected to measure different distances and levels of illuminance. With each Clouclip, five measurements at different distances and light intensities were measured and recorded. Eighty participants wore Clouclips for a week and completed an activity questionnaire afterwards. Results: The intra- and inter-Clouclip coefficients were 1.00 and 0.99 for measuring distance and 1.00 and 1.00 for illuminance, respectively. Within the measurement limit, the maximum relative error was 2.07% for distance and 2.23% for illuminance. Assuming that <30 cm was the typical distance for near-work activities and >1000 Lux was the typical cut-off for outdoor environments, the questionnaire showed a trend of overestimation for both. The greatest overestimation of near-work occurred during the school period [Questionnaire: 4.73 hr (4.73, 5.07) versus Clouclip: 2.16 hr (1.74, 2.78); p < 0.01]. The greatest overestimation of outdoor activity also occurred during the school period [Questionnaire: 1.60 hr (1.33, 1.85) versus Clouclip: 1.21 hr (0.96, 1.50); p < 0.01]. Based on Clouclip, the total time spent outdoors was estimated to be 1.55 hr on school days, of which 0.34 hr occurred after school. For weekend days, however, the duration was only 0.17 hr. Conclusions: Clouclip had excellent precision and accuracy. Although the agreement between the questionnaire and Clouclip was relatively poor, they were able to complement each other to provide a more logical and feasible assessment of exposure to near-work and outdoor activity. Indoor-oriented lifestyles were found to predominate in Chinese children.
AB - Purpose: To validate a novel wearable device that can measure both viewing distance and light exposure, Clouclip, and compare questionnaire estimates regarding near-work and outdoor time with the objective measures obtained using Clouclip. Methods: Fifteen Clouclips were selected to measure different distances and levels of illuminance. With each Clouclip, five measurements at different distances and light intensities were measured and recorded. Eighty participants wore Clouclips for a week and completed an activity questionnaire afterwards. Results: The intra- and inter-Clouclip coefficients were 1.00 and 0.99 for measuring distance and 1.00 and 1.00 for illuminance, respectively. Within the measurement limit, the maximum relative error was 2.07% for distance and 2.23% for illuminance. Assuming that <30 cm was the typical distance for near-work activities and >1000 Lux was the typical cut-off for outdoor environments, the questionnaire showed a trend of overestimation for both. The greatest overestimation of near-work occurred during the school period [Questionnaire: 4.73 hr (4.73, 5.07) versus Clouclip: 2.16 hr (1.74, 2.78); p < 0.01]. The greatest overestimation of outdoor activity also occurred during the school period [Questionnaire: 1.60 hr (1.33, 1.85) versus Clouclip: 1.21 hr (0.96, 1.50); p < 0.01]. Based on Clouclip, the total time spent outdoors was estimated to be 1.55 hr on school days, of which 0.34 hr occurred after school. For weekend days, however, the duration was only 0.17 hr. Conclusions: Clouclip had excellent precision and accuracy. Although the agreement between the questionnaire and Clouclip was relatively poor, they were able to complement each other to provide a more logical and feasible assessment of exposure to near-work and outdoor activity. Indoor-oriented lifestyles were found to predominate in Chinese children.
KW - myopia
KW - near work
KW - outdoor exposure
KW - questionnaire
KW - wearable device
UR - http://www.scopus.com/inward/record.url?scp=85102642894&partnerID=8YFLogxK
U2 - 10.1111/aos.14785
DO - 10.1111/aos.14785
M3 - Article
SN - 1755-375X
VL - 99
SP - e1222-e1235
JO - Acta Ophthalmologica
JF - Acta Ophthalmologica
IS - 7
ER -